LED Driver Compatibility Chart: DALI, 0-10V, TRIAC, Zigbee and BLE

Most dimming failures are not driver failures. They are protocol mismatches: a 0-10V driver wired to a TRIAC dimmer, a Zigbee fixture with no gateway, or a DALI driver on a bus with no controller. This page maps the six protocols we build into our drivers against the wiring, hardware and limits each one needs.

The six protocols at a glance

ProtocolControl wiringTypical dimming rangeGateway or controllerAddressable
Non-dimNone — switch onlyOn / offNoNo
TRIAC / phase-cut2-wire, dimmer in line10–100% typical, load dependentCompatible wall dimmerNo
0-10V2 extra signal wires, polarity matters10–100% or 1–100%0-10V controller or dimmerNo
DALI / DALI-22-wire bus, polarity-free0.1–100%, log curveDALI application controllerYes, individually
Zigbee (Tuya)Wireless mesh1–100% typicalZigbee gateway / hubYes, per device
Bluetooth (Tuya BLE)Wireless, phone-direct1–100% typicalPhone app; gateway only for remote accessYes, per device
2.4G proprietaryWireless, paired remote1–100% typicalPaired remote onlyZone level

Ranges above are what the protocol normally delivers. Always confirm the actual bottom end on the driver datasheet — a driver that claims “1%” but flickers below 5% is a 5% driver in practice.

How each one fails in the field

ProtocolCommon failureWhat to check first
TRIACFlicker at low output, buzzing, limited rangeMinimum load of the dimmer, and whether the dimmer is leading- or trailing-edge
0-10VNo dimming, or inverted behaviourSignal polarity, and whether the controller sinks or sources current
DALIWhole bus dead, or one address missingBus power supply present, bus voltage 16 V, no duplicate addressing
ZigbeeDevices drop off after a weekGateway distance, mesh router density, 2.4 GHz interference from Wi-Fi
BLEWorks in the app, not on the wall switchBLE has no wall control by default — add a BLE remote or scene switch
2.4GTwo remotes control the same zonePairing state — remotes are zone-based, not address-based

Choosing a driver for a 48V magnetic track

On a 48 V system, driver choice is a power budget problem before it is a dimming problem:

  1. Add up the fixture wattage on the circuit, then add 10–20% headroom.
  2. Pick a constant-voltage 48 V DC driver at or above that figure. Do not run a constant-voltage driver at 100% continuously if you expect to add fixtures.
  3. Check voltage drop on the rail. Long runs and thin conductors lose volts; feeding the rail from both ends is often cheaper than a bigger driver.
  4. Match the dimming protocol to what is already on site — not to what the client saw in a showroom.

For AC track the same logic applies per fixture, except the driver sits inside the adapter, so the constraint becomes adapter size and heat rather than a shared box.

Our driver families

Tell us the control system on site and the fixture load, and we will match a driver to it. Send us the specification.