24V 48V Constant Voltage LED Driver 80W-400W
SKU
24V 48V constant voltage LED driver with 180-265VAC input, five 80W-400W ratings, V0 plastic cover and potted housing for home, project and hotel LED lighting.
Description
What is a 24V 48V constant voltage LED driver
A 24V 48V constant voltage LED driver converts mains AC into a fixed low-voltage DC output for LED fittings. This black-gem series unit takes an AC180-265V input and is offered in either 24V or 48V DC, with output ratings from 80W to 320W. A constant voltage supply lets the LED fittings draw the current they need, up to the rating of the chosen model, which makes it a common choice for strip, linear and modular lighting.

The range is built around a private-mould plastic upper cover with a V0 flame-retardant rating. Inside, the components are protected by a potting process, and the circuit uses a resonant topology to keep operating temperature down. The combination is intended for concealed installations where the supply sits above a ceiling or inside a cabinet for long periods.
Because the output voltage is held steady, the same fittings can be used across projects once the voltage is chosen. Only the rating changes between models, so the wiring method stays consistent. Confirm the output voltage and the exact power rating for your model with our team before placing an order.
Models and power ratings
The series has five model codes. GX-921511 is rated at 80W input and 80W output, GX-541921 at 120W, GX-832012 at 200W, GX-982062 at 300W, and GX-992572 at 400W input with 320W output. The first four share an output equal to the input rating; the last model is specified with a lower output figure in the sheet and should be confirmed before ordering.

The 80W and 120W models share a 138×50×27mm body, the 200W model is 205×50×27mm, and the 300W and 400W models are 238×50×27mm. All five use the same 50mm width and 27mm height. This makes the mounting method consistent across the range, with only the length changing as the rating increases.
When comparing models, think about the load you intend to connect rather than the number on the label. Add the per-metre consumption of every LED strip, include any modules on the same circuit, and then choose a rating that leaves a margin above the total. If your calculation sits close to a boundary, move up to the next rating rather than running the supply at its limit.
Two output voltages, one model code
An important detail of this series is that the 24V and 48V versions share the same model codes. The code identifies the power rating and the body size, while the output voltage is a separate choice made when you order. Always state the voltage explicitly in your enquiry so the correct version is shipped.
Do not connect a 48V fitting to a 24V output, or a 24V fitting to a 48V output. The voltage is set at the factory and cannot be changed on site. If you are unsure which voltage your fittings require, check the label on the fitting or send us the product details and we will confirm.
This shared-code approach keeps the range simple for stock planning, but it does mean two physically different supplies can carry the same printed code. Keep the voltage information on your purchase order and on the maintenance record, so a later replacement is ordered correctly. For background on how low-voltage lighting supplies are classified, the Lighting Controls Association resource library provides independent context.
Wide AC input and stable DC output
The AC180-265V input range covers the nominal 220V and 230V mains used in many markets, so the same driver can be specified for projects in different regions without changing a tap or a link. The frequency range covers both 50Hz and 60Hz systems. The output is regulated to a constant voltage, which is the standard form of supply for LED strip and modular fittings that contain their own current limiting.
A wide input is useful on sites where the mains varies between buildings or between times of day. A supply specified for a narrow band can drop out when the voltage dips, while this unit continues to regulate within its stated range. If the site uses a generator or an inverter, confirm the waveform and voltage range with our team before specifying the driver.
Constant voltage output does not force a fixed current through the LEDs. The fittings draw what they need, up to the maximum stamped on the driver, so a lighter load simply runs below the rating. This is why one driver can serve a short strip and a longer strip of the same voltage, provided the combined load stays within the rating. Check the output with a meter after commissioning.
Plastic cover and flame-retardant build
The upper cover is made from a private-mould plastic component with a V0 flame-retardant rating. The specification sheet describes the unit as a classic full-power design intended for home, project and hotel lighting. A plastic cover keeps the weight down and allows an insulated housing around the terminals, which is useful where the supply is handled during installation.
Flame retardancy is a material property, not a claim that the unit can be used in any location. Follow the installation rules for the country of use and keep the driver away from sources of open flame. The sealed cover also limits access to the internal components, so do not attempt to open the unit; a faulty supply should be replaced rather than repaired on site.
Before fixing the unit, check that the surface is flat and that there is room for the cable to enter at both ends. The compact 27mm height allows it to sit in shallow cavities where a larger box would not fit. Leave clearance around the housing so that heat can escape during operation.
Potting process and moisture protection
The internal components are protected by a potting process. The specification sheet lists protection against insects, moisture and dust, which addresses the three things most likely to affect a supply mounted in a concealed space. Potting holds the components in place, so vibration and movement during transport are less likely to loosen a joint.
This matters in ceiling voids, cabinet tops and hotel service areas, where a supply may remain untouched for years. Dust that settles on an exposed board can hold moisture and shorten its life; a potted unit avoids much of that exposure. The construction also reduces the chance of small insects bridging the terminals.
Potting does not make the unit waterproof. It is intended for dry indoor locations. Do not install it outdoors or in a damp room without a suitable protective enclosure, and keep the terminal area accessible so the wiring can be inspected. Clean the exterior with a dry cloth rather than a wet one.
Resonant topology and operating temperature
The circuit uses a resonant topology, described in the specification sheet as giving more efficient conversion and a lower operating temperature. Lower temperature is important for a supply that runs for long hours in a confined space, because heat is the main factor that shortens the life of the internal components.
When a driver runs cooler, it needs less derating in a warm environment and the fittings see a more stable output over time. Keep the housing clear of insulation and do not stack cables over it, so the benefit is not lost after installation. A supply in a sealed box will still trap heat even if the circuit itself is efficient.
Compare efficiency at the load you will actually use rather than at a single quoted figure. A driver running at a moderate fraction of its rating will usually operate cooler than one held near its maximum. If the ambient temperature is high, reduce the connected load further than the usual margin.
Five-year warranty and service life
The specification sheet states a five-year warranty for this series. That is a longer period than many general-purpose supplies, and it reflects the intended use in installed lighting where access for replacement is difficult. Ask our team for the written warranty conditions before you include them in a contract or tender document.
A warranty is separate from the expected service life. The potted construction and the lower operating temperature both help the unit last, but correct sizing and correct wiring matter more than any single design feature. A supply asked to deliver more than its rating will age faster than one running within its design range.
Keep the purchase record and the model code with the installation, including the chosen output voltage. If a unit needs to be returned, having the code and voltage available avoids sending the wrong replacement. For other fixed-output options, our non-dimming driver range and ultra-thin light box supply offer further choices.
Typical applications
The specification sheet lists home, project and hotel lighting as the intended settings. In practice, a 24V 48V constant voltage LED driver of this format is used for LED strip and COB strip runs, linear lighting channels, cabinet and wardrobe lighting, display cases and shelves, cove and perimeter lighting, and furniture-integrated lighting. The 48V version suits longer runs where voltage drop is a concern.
In a hotel corridor, the supply is often mounted above the ceiling line, close to the strip so the cable run stays short. In a retail fit-out it sits behind a display panel, and in a residential project it may be placed above a wardrobe. The DIP-free, fixed-output design keeps commissioning simple.
This series is not a dimming controller and is not a magnetic track power supply. If the project needs a 0-10V or Triac control signal, or a central supply for a 48V magnetic track, select the matching product from our LED driver category or our dimmable driver range instead.
How to size the driver for your LED load
Add up the wattage of every fitting on the circuit, then choose a rating above that total. A common working rule is to keep the connected load at about 80% of the driver rating, which leaves room for temperature rise and later additions. For example, a 24V strip rated at 12W per metre and 8 metres long draws 96W, so the 120W model is a closer match than the 80W model.
Voltage must match exactly: a 48V strip cannot be powered from a 24V output. For long runs, voltage drop becomes visible at the far end. Split the load across two drivers fed from opposite ends rather than running one long cable from a single supply. Send us the total load, the output voltage and the available space, and we will confirm the model.
Remember that the model code does not state the voltage. Write the voltage on the order and check the label on the driver when it arrives. If the project mixes 24V and 48V fittings, use separate drivers for each voltage rather than trying to share one supply.
Installation and wiring notes
Mount the unit on a flat surface using the fixing points provided. Keep the housing clear of insulation and allow air to circulate around it. The driver is intended for dry indoor use within the stated environment; where a location is exposed to moisture or dust, place it inside a suitable enclosure. Do not exceed the rated output.
Disconnect the mains before wiring. Strip each conductor to the length marked on the terminal, insert it fully and check that it is held firmly. Polarity on the DC side matters, so check the output with a meter before connecting the LED load. Qualified electricians should carry out the installation in line with local wiring rules.
Plan the cable run before fixing the unit. Keep the DC runs short and use cable of adequate cross-section for the current: a 300W output at 24V needs a larger conductor than an 80W output, and a long run adds voltage drop that shows as dimmer light at the far end. Label the output voltage and polarity at the terminal so a later service visit does not require tracing the whole run.
After commissioning, record the model code, the output voltage and the connected load on the maintenance sheet. Tell us the wattage, output voltage and quantity if you need a datasheet, MOQ and lead time. For general reading on LED control and constant-voltage supplies, see this LED dimming basics reference.








