Photometric Files (IES and LDT)

Lighting designers need photometric files before a product can be specified. This page explains which files we can supply, in which format, and how to get them for a specific model.

What the two formats are for

FormatStandardUsed by
IES (.ies)IES LM-63DIALux evo, AGi32, Relux, CalcuLux — the default in North America and Asia
LDT (.ldt)EULUMDATDIALux, Relux — the European convention

Both describe the same thing: how much light the fixture emits at every angle. A calculation built on a generic file instead of the actual product produces a lighting design that does not survive commissioning.

What we can supply

  • IES and LDT files for track lights, downlights, spotlights and wall washers where a photometric test report exists
  • Beam-angle variants of the same body, so you can compare 24° and 36° optics in the same calculation
  • Files for both AC track and 48V magnetic track fixtures
  • Lumen output and wattage stated on the same basis as the datasheet, so the calculation matches the quotation

One honest caveat: not every model in our catalogue has an individual test report. Some are supplied from a family report covering the same optic and LED platform. Tell us the models you need and we will confirm exactly what exists rather than send you a file that does not match the product.

How to request files

  1. Send the model list. Model codes are on each product page and on our quotations. A photo of the page works if the code is hard to copy.
  2. Tell us the format. IES, LDT, or both. If you use DIALux evo, say so — that decides the file convention.
  3. We confirm availability within one business day, usually the same day.
  4. You receive the files by email, named by model and beam angle, ready to import.

Send requests to [email protected] with the subject line “IES / LDT file request”, or use the contact form. If you are working to a deadline, say so in the first line and we will prioritise the models you need first.

Model list template

Copy this into your email and fill in the rows — it saves a round trip:

Project: [name / city]
Software: [DIALux evo / Relux / AGi32]
Required format: [IES / LDT / both]
Deadline: [date]
Model code            | Beam angle | Qty in design
----------------------|------------|-------------
[ e.g. TSMC-48V-... ] | 24 deg     | 18
[ ... ]               | 36 deg     | 6

Why the file matters more than the datasheet

A datasheet gives you lumens and wattage. A photometric file gives you the distribution — where those lumens actually land. Two fixtures with identical lumen output can produce completely different uniformity, glare and wall-wash results. If a tender asks for EN 12464-1 or IES RP-1 compliance, the calculation has to be built on the real file, not an assumption.